DigiMod_User_guide.pdf

(5406 KB) Pobierz
6/24/02
DigiMod 500
DigiMod 1000
DigiMod 1500
DigiMod 2000HV
DigiMod 1000NPS
User Manual
COD: MAN-DGM-USER_MAN19-EN-11
NOV 2007
Caution
DigiMod 500/1000/1500/2000HV/1000NPS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
!
IMPORTANT SAFETY INSTRUCTIONS!
! Read these instructions !
! Keep these instructions !
! Heed all warnings !
! Follow all instructions !
serviceable parts inside. Refer servicing to qualified service personnel.
WARNING:
To prevent fire or electric shock, do not expose this equipment to rain or
moisture.
SAFEGUARDS:
Electrical energy can perform many useful functions. This unit has been
engineered and manufactured to assure your personal safety. Improper use can result in
potential electrical shock or fire hazards. In order not to defeat the safeguards, observe the
following instructions for its installation, use and servicing.
NOTES: This equipment has been tested and found to comply by Competent Body (Directive
89/336/EEC-EMC) pursuant to the product family standard for audio professional use:
EN 55103-1 and EN 55103-2 standard (with the limits for E1 and E2 electromagnetic
environment); EN61000– 3 – 2 , EN 61000 – 3 - 3
This is a Class A product (ClassB from s/n 18000). In a domestic environment this product may
cause radio interferences in which case the user may be required to take adequate measures.
This equipment has been tested and found to comply by Notified Body 0715 (Directive 73/23/EEC
L.V) pursuant to the audio apparatus safety requirements: Standard EN 60065.
CAUTION:
To reduce the risk of electric shock, do not remove the cover. No user-
Warning Notices
Location
Install the amplifier in a ventilated enclosure (IP20 at least), where it will not be directly exposed to high
temperature or humidity.
Do not install the amplifier in a location that is exposed to direct rays of the sun, or near to hot appliances or
radiators. Excessive heat can adversely affect the operation and internal components. Installation of the
module in a damp or dusty environment may result in malfunction or accident.
Placing and using the amplifier for long periods on heat-generation sources will affect performances. Avoid
placing the amplifier on heat-generating sources. Install this amplifier as far as possible from tuners and TV
sets. An amplifier installed in close proximity to such equipment may cause noise or degradation of the
picture.
Precautions regarding installation
07/11/07
Powersoft s.r.l.
-
P. IVA n. 04644200489 – Via E.Conti, 5 Scandicci - Tel.: (+39) 055 7350230- Fax: 055 7356235
2
Safety rules
DigiMod 500/1000/1500/2000HV/1000NPS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
!
This device must be powered exclusively by earth connected mains sockets in electrical networks
compliant to the IEC 364 or similar rules.
Is absolutely necessary to verify this fundamental requirement of safety and, in case of doubt,
require an accurate check by a qualified personal.
Is absolutely necessary to ground this device using the proper earth connection on the metal frame
of the chassis, use M4 nut and proper Grover type washer to secure the earth terminal lug.
The constructor cannot be considered responsible for eventual damages caused to persons, things
or data for the missing of accurate earth link.
Provide the installed unit with bipolar switch to unconnect both mains connection with at least 3mm
of distance of the switch contacts.
Before powering this device verify that the module is supplied with the correct voltage rating.
Verify that your mains connection is capable to satisfy the power ratings of the device.
Do not spill water or other liquids into or on the unit.
Do not use this unit if the electrical power cord is frayed or broken.
Do not remove the cover. Removing the cover will expose you to potentially dangerous voltage.
No naked flame sources such like lighted candles should be placed on the module.
Contact the authorized center for ordinary and extraordinary maintenance.
Input mains and output power connection wirings must not to be accessible to the user.
The enclusure apparatus shall be designed so that the start and spread of fire is prevented as
much as possible , and shall not give rise to danger of fire to the surrounding of the apparatus.
This is achieved as follows:
- by using good engineering practice in design and production of the enclosure apparatus to
avoid potential ignition sources
- by using materials of low flammability for internal parts in the vicinity of potential ignition
sources
- by using fire enclosures to limit the spread of fire
07/11/07
Powersoft s.r.l.
-
P. IVA n. 04644200489 – Via E.Conti, 5 Scandicci - Tel.: (+39) 055 7350230- Fax: 055 7356235
3
Specifications
DigiMod 500/1000/1500/2000HV/1000NPS
SPECIFICATIONS
GENERAL
Type .......................................................................................... high efficiency 1/2 channels amplifier for professional applications
POWER REQUIREMENTS
DigiMod1000 / (DigiMod500)
DigiMod1500
230Vrms mains voltage selection ............................................... AC 230+/ - 10 % 50/60 Hz / 1.6 (1.0) A
115Vrms mains voltage selection ............................................... AC 115+/ - 10 % 50/60 Hz / 2.6 (2.0) A
230Vrms mains voltage selection ............................................... AC 230+/ - 10 % 50/60 Hz / 2.2 A
115Vrms mains voltage selection ............................................... AC 115+/ - 10 % 50/60 Hz / 3.6 A
DigiMod2000HV
230Vrms mains voltage selection ............................................... AC 230+/ - 10 % 50/60 Hz / 2.9 A
115Vrms mains voltage selection ............................................... AC 115+/ - 10 % 50/60 Hz / 5.5 A
DigiMod500+DigiMod1000NPS/ DigiMod1000+DigiMod1000NPS
POWER REQUIREMENTS DigiMod1000NPS
230Vrms mains voltage selection ............................................... AC 230+/ - 10 % 50/60 Hz / 2.2 A
115Vrms mains voltage selection ............................................... AC 115+/ - 10 % 50/60 Hz / 3.6 A
Power bus .................................................................................. Dc +/- 75 V (+8% -20%)@(7 A)
Auxiliary supply........................................................................... Dc +15V (+30% -15%)@(0.7 A) / -15 V (+30% -15%)@ (0.3 A)
+7V (+30% -15%)@(0.5 A)
All requirements are provided by a master DigiMod 500 orDigiMod 1000 thru slave connector
DIMENSIONS / WEIGHTS
Weight ........................................................................................ 1.0 Kg DigiMod500
Weight ........................................................................................ 1.1 Kg DigiMod1000
Weight ........................................................................................ 1.15 Kg DigiMod1500/2000HV
Weight ........................................................................................ 0.6 Kg DigiMod1000NPS
External dimensions ................................................................... 216mm (W), 122mm (D), 51mm (H) DigiMod500/1000/1500
External dimensions ................................................................... 146mm (W), 122mm (D), 51mm (H) DigiMod1000NPS
AUDIO SECTION
Slew Rate (8Ω) ....................................... 50V/Us
Gain (Digimod500/1000/1500/1000NPS) ....... 32 dB
S/N ratio ................................................. 105 dB/A
Gain (Digimod2000HV) .................................. 38 dB
Distortion ................................................ <0.5% (THD, DIM, SMPTE)
Output ............................................................ Unbalanced to ground
Inputs...................................................... Balanced to ground
Bandwidth ...................................................... 10 Hz - 30KHz
Impedance.............................................. 10 KΩ
Damping factor 500Hz/8Ω (Digimod500/1000/1500/1000NPS) ................ > 500
Damping factor 500Hz/8Ω (Digimod2000HV) ........................................... > 100
Power continuous
(1KHz, 0.5% THD) 4Ω = 450W 8Ω = 260W
Power EIAJ
(1KHz, 1% THD) 4Ω = 530W 8Ω = 280W
POWER SPECIFICATIONS
DigiMod500
(measured at 115 or 230V AC, 50/60Hz)
Power continuous, all channels driven
(1KHz, 0.5% THD) 4Ω = 3X 350W 8Ω = 3X 230W
Power EIAJ, all channels driven
(1KHz, 1% THD) 4Ω = 3X 410W 8Ω = 3X 250W
Power continuous, all channel driven
(1KHz, 0.5% THD) 4Ω = 4X 310W 8Ω = 4X 210W
Power EIAJ, all channels driven
(1KHz, 1% THD) 4Ω = 4X 375W 8Ω = 4X 230W
Bridged 8Ω = 2X 750W 16Ω = 2X 460W
Power continuous, both channels driven
(1KHz, 0.5% THD) 8Ω = 2X 780W 16Ω = 2X 440W
Power EIAJ, both channels driven
(1KHz, 1% THD) 8Ω = 2X 1050W 16Ω = 2X 570W
Bridged 16Ω = 2100W 32Ω = 1140W
DigiMod500+DigiMod1000NPS
DigiMod1000
Power continuous, both channels driven
(1KHz, 0.5% THD) 4Ω = 2X 390W 8Ω = 2X 240W
Power EIAJ, both channels driven
(1KHz, 1% THD) 4Ω = 2X 500W 8Ω = 2X 270W
Bridged 8Ω = 1000W 16Ω = 520 W
DigiMod1000+DigiMod1000NPS
DigiMod1500
Power continuous, both channels driven
(1KHz, 0.5% THD) 4Ω = 2X 590W 8Ω = 2X 330W
Power EIAJ, both channels driven
(1KHz, 1% THD) 4Ω = 2X 750W 8Ω = 2X 370W
Bridged 8Ω = 1500W 16Ω = 740W
DigiMod2000HV
FUNCTIONS
Thermal protection (over-temperature power limiting, thermal shutdown)
Short-circuit / overload output protection
Clip limiter, Permanent signal limiter, High frequency protection
Auxiliary output voltage (±12V regulated , 200mA )
Bypass outputs for external active/passive filters
Digimod500/1000/1000NPS: Temperature controlled Fan output (CN10)
Digimod1500/2000HV: Temperature controlled Fan
DSP based or Analog processing plugin optional boards
07/11/07
Powersoft s.r.l.
-
P. IVA n. 04644200489 – Via E.Conti, 5 Scandicci - Tel.: (+39) 055 7350230- Fax: 055 7356235
4
Connection description
DigiMod 500/1000/1500/2000HV/1000NPS
CN3:
CN11:
PIN1, POWER OUTPUT CHANNEL 1 POSITIVE
PIN2, POWER OUTPUT CHANNEL 1 NEGATIVE
PIN1,
PIN2,
PIN3,
PIN4,
SIGNAL GROUND CHANNEL 1
BALANCED INPUT + CHANNEL 1
BALANCED INPUT – CHANNEL 1
OUTPUT TO EXTERNAL VOLUME CONTROL CHANNEL 1,
R Potentiometer = 1KOhm to 2.7Kohm, linear type
(remove J1 placed on pins 3,4 of CN17 to insert external potentiometer)
PIN5, INPUT FROM EXTERNAL VOLUME CONTROL CHANNEL 1,
CN14:
PIN1, AUXILIARY SUPPLY OUTPUT GROUND
PIN2, MUTE CONTROL PIN, PULL DOWN TO GROUND TO MUTE BOTH
OUTPUTS
PIN3, +12VOLTS DC REGULATED AUXILIARY OUTPUT,
CURRENT SHALL NOT EXCEED 200 mA.
PIN4, -12VOLTS DC REGULATED AUXILIARY OUTPUT,
CURRENT SHALL NOT EXCEED -200 mA.
PIN1,
PIN2,
PIN3,
PIN4,
SIGNAL GROUND CHANNEL 2
BALANCED INPUT + CHANNEL 2
BALANCED INPUT – CHANNEL 2
OUTPUT TO EXTERNAL VOLUME CONTROL CHANNEL 2,
R Potentiometer = 1KOhm to 2.7Kohm, linear type
(remove J2 placed on pins 1,2 of CN18 to insert external potentiometer)
PIN5, INPUT FROM EXTERNAL VOLUME CONTROL CHANNEL 2,
PIN1, POWER OUTPUT CHANNEL 2 POSITIVE ( ground connected)
PIN2, POWER OUTPUT CHANNEL 2 NEGATIVE (hot pole, CHANNEL 2 has reversed
.
polarity to have bridged output with CHANNEL 1 directly between positive output of
.
CH1 with negative output of CH2; input stage of CH1 is phase reversing ).
PIN1, PIN2, MAINS INPUT FOR BOTH 115V AND 230 OPERATION,
SEE CN2 FOR VOLTAGE SELECTION.
PIN1,PINS2 OPEN FOR 230VAC OPERATION, CONNECT PIN1 TO PIN2 FOR 115VAC
OPERATION. DEFAULT SELECTION 230VAC.
(SEE PAG 10/13 DRAWING FOR LOCATION)
PIN1,PIN3 TO NEGATIVE WIRE OF EXTERNAL 24VDC FAN
PIN2 TO POSITIVE WIRE OF EXTERNAL 24VDC FAN
PIN1 TO 72 SEE PAGE 13
CN12:
CN7:
CN1:
CN2:
CN10:
CN8:
CHECK PROPER CHASSIS EARTH CONNECTION BEFORE OPERATE
07/11/07
!WARNING!
CHECK PROPER VOLTAGE SELECTION BEFORE OPERATE
Powersoft s.r.l.
-
P. IVA n. 04644200489 – Via E.Conti, 5 Scandicci - Tel.: (+39) 055 7350230- Fax: 055 7356235
5
Zgłoś jeśli naruszono regulamin