Installation Instruction_Electrical.pdf

(353 KB) Pobierz
Installation Instruction, Electrical
Installation Instruction, Electrical
Applicable for C902, C902c
Contents
1
2
General............................................................................................................................. 2
Go/No Go Testing............................................................................................................ 2
2.1
Test Set-Up Go/No Go test................................................................................ 2
2.2
Test Set .............................................................................................................. 3
2.3
RF Connections Antenna Coupler..................................................................... 3
2.4
RF Connections Probe (optional) ...................................................................... 3
Calibration....................................................................................................................... 4
3.1
GSM Calibration Test set up – SERP (only authorized centers)....................... 4
3.2
Test Set .............................................................................................................. 5
3.3
GPIB card and cable.......................................................................................... 5
3.4
Sony Ericsson programming interface – SEPI .................................................. 5
3.5
USB Cable......................................................................................................... 5
3.6
Power Supply (optional).................................................................................... 5
3.7
Battery Eliminator (Dummy Battery)................................................................ 6
3.8
RF Connection (GSM Calibration only) ........................................................... 6
3.9
Sony Ericsson programming interface cable (GSM Calibration only).............. 6
3.10
Calibration Shield box setup (WCDMA or GSM Calibration) ......................... 7
Software Loading.......................................................................................................... 10
4.1
Set up............................................................................................................... 10
4.2
Computer ......................................................................................................... 11
4.3
USB Activation Dongle................................................................................... 11
4.4
Sony Ericsson programming cable – DCU-65 ................................................ 11
Software ......................................................................................................................... 11
5.1
EMMA III........................................................................................................ 11
5.2
SERP Go/No Go Test Script ........................................................................... 12
5.3
SERP Calibration (only authorized centers).................................................... 12
Lead-Free Electrical Repair......................................................................................... 13
Revision History............................................................................................................ 15
3
4
5
6
7
1212-7766 Rev 2
©
Sony Ericsson Mobile Communications AB
Installation Instruction, Electrical
1
General
The Electrical Installation Instructions describe the procedures for installing all of the
hardware and software needed to perform testing at an Electrical level for the Sony
Ericsson products specified.
2 Go/No Go Testing
There are two options for performing a Go No/Go test. One is to use an RF Probe and
cable, and the other is to use an antenna coupler together with a shielding box.
2.1 Test Set-Up Go/No Go test
All test hardware necessary for this test set up is documented in the Mechanical or
Electrical Equipment Lists.
COMPUT
ER
PRINT
ER
GPIB
CABLE
T TS
ES ET
OPT
IONAL
OPT
IONAL
RF CABLE
RF PROBE
HOLDER
*
OPT
IONAL
RF PROBE
RF S
HIELD
BOX
BAT ERY AND
T
BAT ERY COVER
T
*
T RF Probe Holder and the Battery Cover may not be used for every produc t.
he
S the Installation Instructions and T Instruc tions for details.
ee
est
*
1212-7766 Rev 2
©
Sony Ericsson Mobile Communications AB
2(15)
Installation Instruction, Electrical
2.2 Test Set
A Quad Band GSM 850/900/1800/1900 and WCDMA (Bands I, II and V) Test Set
approved according to the Electrical Equipment List must be used.
It should be installed according to the Instrument Manufacturer’s Instructions.
2.3 RF Connections Antenna Coupler
Connect the RF Cable between the RF-port of the Test set and the RF Shield box. The
Antenna Coupler should be installed into the RF Shield Box according to the
manufacturer’s instructions.
2.4 RF Connections Probe (optional)
Connect the RF-cable between the RF-port of the Test set and the RF Probe. Attach the
RF Probe to the phone according to the information in the Test Instruction Electrical.
1212-7766 Rev 2
©
Sony Ericsson Mobile Communications AB
3(15)
Installation Instruction, Electrical
3 Calibration
There are two types of calibration; GSM and WCDMA. Due to the sensitivity of the
phone from outside interference during WCDMA calibration, a Shield box and Service
Tool Test Interface are required for WCDMA Calibration. These can be also used for
GSM Calibration. Section 3.1 depicts a GSM only setup. For GSM only, follow sections
3.2 thru 3.10. For WCDMA or GSM, follow sections 3.2 thru 3.6 and 3.11.
3.1 GSM Calibration Test set up – SERP (only authorized
centers)
COMPUT
ER
GPIB
CABLE
T TS
ES ET
RF PROBE
HOLDER
RF CABLE
RF
PROBE
*
BAT ERY
T
AND
BAT ERY
T
COVER
POWER S
UPPL
Y
BAT ERY ELIMINAT
T
OR
AND MODIFIED
BAT ERY COVER
T
*
S
EPI
CABLE
S
EPI
US
B
CABLE
CS -60
T
CHARGER
OPT
IONAL
*
*
T RF Probe Holder, Battery Cover, and Modified Battery Cover may not be used for every produc t.
he
S the Installation Instruc tions and T Instructions for details.
ee
est
1212-7766 Rev 2
©
Sony Ericsson Mobile Communications AB
4(15)
Installation Instruction, Electrical
3.2 Test Set
A Test Set approved according to the Electrical Equipment List must be used.
It should be installed according to the instrument Manufacturer’s Instructions.
3.3 GPIB card and cable
Use a GPIB card and cable according to the Electrical Equipment List. Use the GPIB
cable to connect the GPIB card in the computer to the test instrument.
3.4 Sony Ericsson programming interface – SEPI
The USB programming interface is delivered with the necessary software and instruction
for installation. The USB programming interface (SEPI) should be connected to a USB-
port on the computer.
3.5 USB Cable
The A-B Plug-Plug cable is the interface between the computer and the USB
programming interface (SEPI). Connect the cable between the USB programming
interface and the computer.
3.6 Power Supply (optional)
A Power Supply according to Electrical Equipment List may be used.
Set the output of the Power Supply as follows
Voltage: 3.8Vdc
Current: 2.0Amps
It is preferred that a standard fully charged battery be used for
calibration. However, a second option is to use the Battery Eliminator
(Dummy Battery) with a power supply that meets the requirements
documented in the Electrical Equipment list.
NOTE!
1212-7766 Rev 2
©